traction control RENAULT SCENIC 2009 J84 / 2.G Air Conditioning Climate Control Workshop Manual

Page 48 of 60

62B-48
CLIMATE CONTROL
Fault finding – Fault Finding Chart62B
V3 MR-372-J84-62B000$110.mif
Vdiag No.: 44
ALP 4 Inefficient windscreen demisting
NOTESOnly consult this customer complaint after a complete check using the diagnostic
tool.
Special notes:
Check that the inside of the windows are not greasy, as this lowers the efficiency
of the demister.
Check that the air extraction vents are not blocked.
Repair if necessary.
Is the fault still present?
YES
Ensure that there are no water leaks into the passenger
compartment which would significantly increase the humidity
and reduce the effectiveness of the demisting.
Repair if necessary (see ALP 12).
Is the fault still present?
YES
Check that the compressor is operating correctly by running command: AC008 Compressor command
(Protection and Switching Unit command mode) or by operating the air conditioning (press AC button).
Repair if necessary (see ALP 8 No cold air, in section 62A).
Check that the condensation drain ring (water from the evaporator) is not obstructed (underneath the body).
Repair if necessary.
Is it an air distribution fault?
NO
NO
NO
YESEnd of fault finding procedure.
End of fault finding procedure.
See ALP 2.
AFTER REPAIRPerform a complete check using the diagnostic tool.
ACREG X84 1.1
Edition 2